Email:hytech@hytechchina.com
Wechat:hytechchina1688
Direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).
Cavity | T-11A |
Series | 1 |
Capacity | 15 gpm |
Maximum Operating Pressure | 5000 psi |
Factory Pressure Settings Established at | 2 in³/min. |
Maximum Valve Leakage at Reseat | 10 drops/min. |
Check Cracking Pressure | 40 psi |
Response Time - Typical | 2 ms |
Adjustment - No. of CW Turns from Min. to Max. setting | 5 |
Valve Hex Size | 7/8 in. |
Valve Installation Torque | 30 - 35 lbf ft |
Adjustment Screw Internal Hex Size | 5/32 in. |
Locknut Hex Size | 9/16 in. |
Locknut Torque | 80 - 90 lbf in. |
Model Weight | 0.44 lb. |
CKCB-XCN | CXHA-XAN | PRDL-LSN | CBBC-LHN |
CKEA-XAN | CKED-XAN | CKEB-XAN | CKEC-XAN |
RPKC-LWN | RBAA-KEN | RDDA-LAN | CBLA-LHN |
CXEE-XCN | CNAD-XCN | RPCC-LAN | RPEC-LAN |
RPGC-LAN | RPIC-LAN | RPEE-LAN | RPGE-LAN |
RPIE-LAN | RDDA-LAN | RDBA-LAN | RVCD-LAN |
RDFA-LAN | RDHA-LAN | RBAC-LAN | RBAA-LAN |
PBBB-LAN | PBDB-LAN | CBEA-LHN | RPEC-LAN |